The steel used for your Pioneer Building will have a minimum yield point of 50 KSI with a minimum tensile strength of 65
KSI, ASTM A792 grade. Each customer will be supplied blueprint engineered drawings sealed by a certified engineer.
Specifications
for Arch Type Building Systems
Note: These specifications are designed to be used as a general guideline when preparing performance specifications for an arch type building system.
1.0 Scope
This section covers the design, material, fabrication, shipment
and erection of arch based building systems. All material, erection and field work included and excluded shall be in
accordance with the "Code of Standard Practice" of the building
construction industry.
2.0 Description
All the various models of buildings listed below utilize the
basic bolted arch panel concept to form spans of various shapes.
The pre-punched panel bolted construction can be utilized for
permanent structures or be easily dismantled for reassembly with
virtually no damage to the members. This portability is an
added feature not normally encountered in the pre-engineered
building field.
2.1 Building Size
Building sizes range from 10' wide spans in our Mini models up
to unlimited widths in our "multi-span" arch systems. Lengths
are unlimited, based on 18" increments for the Mini building and
2'-0" for all other models. Peak heights and sidewall
clearances vary for different model types and cover a wide range
of combinations.
2.2 Building Type
Back
to top
(a) Basic Models
A single radius clear span arch structure. Standard sizes range
from 19' wide to 100' wide with height being limited to 1/2 span
or less.
(b) Open Sided
A single radius, partial arch structure, clear span with
structural frame supports on open side. Standard sizes range
from 19' wide to 50' wide with open side clearances of 8', 10',
12', 14', 16' and varying bay spacing.
(c) S Series
A straight sided, multiple radius clear span arch system.
Standard sizes range from 20' wide to 50' wide, with straight
sides and varying center heights.
(d) Econospan
A straight roof, straight sided clear span building system with a uniform roof slope of 18 degrees. Standard sizes range from 20' wide to 30' wide with varying center heights.
(e) Support Arch
A single radius, arch structure with interior center column
support system. Standard sizes range from 80' wide to 120' wide with
varying center peak heights.
(f) Roof Systems
A single radius clear span low profile arch structure designed
to act as a roof system utilizing conventional wall designs as
sidewall support. Standard sizes range from 30' wide to 90'
wide with heights in the 10' to 30' region.
(g) Multiple Arch Spans
A series of single radius arch structures sharing a common
structural support system as an interior wall. Standard sizes
range from 30' to 70' wide for each individual span, joined side
by side in any number of combinations from double span to triple
span and upward.
(h) Conveyor Covers
Either single radius or multiple radius clear span arch
structures designed to cover standard single or double conveyors
and acting as a gallery. Standard sizes range from 10' wide to
30' wide with heights and sidewall clearances to accommodate any
combination of conveyor and walkway systems.
(i) Mini Buildings (Security Shelters)
Single radius clear span arch structure with straight sides.
Designed to provide tamper proof, secure cover for remote
storage locations such as well-head valves, oil field storage,
etc. Standard sizes range from 10' wide to 20' wide with
various peak heights to suit different applications.
Back to top
2.3 Arch Structures
All arch structures, other than Mini Buildings, utilize our
standard 2'W X 10'L corrugated prepunched panels as the basis of
the design. Panels are cold formed to various radii as required
and bolted together to achieve the desired span. Panels are
gang punched to ensure uniformity of manufacture and ease of
assembly.
2.4 End wall Systems
All end walls are designed using our standard 18" center 3 1/4"
deep corrugated, prepunched panels to form various end wall arrangements as required. By altering the pattern of panels any
size opening can be achieved to accommodate roll-up, overhead,
swing or sliding door systems.
Back
to top
2.5 Building Loading
General
Basic design loads shall include live, snow, wind and earthquake
(if applicable) in addition to dead load. All loading shall be
in accordance with the governing building code as prescribed by
local building authorities.
Snow and Wind Load
Design snow and wind load shall be based on the specified ground
snow load and wind pressure respectively. Distribution of
loading over the building envelope shall be in accordance with
the applicable governing building codes for the location
involved.
Seismic Loads
If applicable, the effect of dynamic loads must be considered in
combination with other loads.
Back to top
3.0 Design and Plans
Plans and Specifications
The manufacturer shall submit plans and specifications in
sufficient detail to establish the design of the structure under
consideration, including but not necessarily limited to, all
loading conditions, material grades and geometry of the panel
section.
Design Certification
Upon request, the manufacturer shall furnish a letter of design
certification signed and sealed by a registered professional
engineer.
4.0 Materials
Materials shall be new and shall meet or exceed the mechanical
and physical properties required by the design and the
fabrication process.
4.1 Material Certification
Upon request the manufacturer shall furnish a letter certifying
that current inventory materials meet or exceed the mechanical
and physical requirements of the design and fabrication process.
Laboratory or mill test reports of current inventory materials
shall be available for inspection if required.
Back
to top
4.2 Fabrication
Fabrication tolerances shall not exceed those recommended by the
governing building codes.
5.0 Arch Systems Materials
Basic arch panel structures are available in the following
material:
Galvalume - .027" to .066" AZ180 Galvalume steel (Heavy Commercial
Coating with 20 Year Mill Warranty) passivated with regular mill
finish.
5.1 Fasteners
Fastener location and spacing shall be in accordance with
manufacturer's standards for the roof (arch) and wall panels.
Basic structural fasteners are as follows:
Indented Hex Washer Head Machine Screws, Organic Coating,
Assembled with Neoprene Washers
5/16 - 18 X 3/4"
5/16 - 18 X 1"
3/8 - 16 X 1"
Square Machine Screw Nuts, Organic Coating
5/16 - 18
3/8 - 16
Back to top
5.2 Sealant
Manufacturer shall provide, when requested, quality metal
building tape sealant for all roof seams and joints. Sealant is
a butyl rubber compound used to seal panels against air, dirt,
ice and water. Material is compatible with most plastics,
foams, rubber and other metal building components.
5.3 Trim and Flashing
Special manufactured standard double angle flashing system is
utilized at all end wall to roof transitions. Flashing is made
from heavy gauge (18 & 22) to provide some structural stability
as well as finishing features.
6.0 Accessories
Manufacturer provides a complete array of standard accessory
items available for all structure types.
Back
to top
6.1 Swing Doors
Construction - Pre-hung 4' X 7' panel assembled door suitable
for padlock type closure.
6.2 Sliding Doors
Top Hung heavy duty panel construction, with 14 gauge framing
and 22 gauge corrugated door panels. Doors are equipped with
pull handles, heavy duty ball bearing rollers, interlocking
edge, bottom seals, latch and lock device.
6.3 Hangar Doors
Manufacturer has a full range of standard double track top hung
sliding hangar doors. Construction is as standard sliding doors,
and leafs are on a double track system to allow for partial
opening. Sizes range from 30' in width up to 80' in width in
heights for 10'-0" to 20'-0".
6.4 Sectional Overhead Doors and Roll Up Doors
Framed openings shall be all steel heavy duty bolted
construction. Choose from a wide variety of commercial overhead doors.
Back
to top
6.5 Skylights, Door Lights, Wall Lights
Manufacturer has a wide variety of fiberglass panels formed to
the shape of the basic building components. Material is a
quality 12 oz., 16 oz., or 24 oz. fiberglass panel designed to
install as a replacement for standard steel sections for ease of erection.
6.6 Ventilators
Continuous circular gravity type 12" diameter ventilator or 12"
diameter turbine ventilators utilizing heavy duty ball bearing
type shafts for quiet long lasting service.
6.7 Roof and Wall Insulation
Arch type structures are compatible with all conventional
insulation methods, spray on, fiberglass rolls or rigid foam.
Back
to top
7.0 Warranties
Manufacturer's Warranty shall warrant the following:
1) All buildings are designed in accordance with the local
governing building code to withstand the published wind and snow
loadings when provided by the seller to the manufacturer.
2) All materials will be free of defect in material and
workmanship.
Back to top
8.0 Shipping
All arch structures have unique compact stacking capability due
to the nesting of the standard panel components. This stacking
feature greatly reduces the bulk found in normal building
construction and reduces freight costs.
9.0 Erection
The manufacturer supplies detailed comprehensive erection guides
and blueprints for all building models. These erection guides
contain valuable information to minimize construction problems
and speed up installation.
Back
to top |